Here >> List > Dissolved Gas Releaser
>>Dissolved Gas Releaser

Dissolved gas flotation pressure on the Clean Water Act is a new water treatment technology,The dissolved gas is released from the water and micro-bubbles in water use adhesion with solid impurities in the care of bubbles floating to solid-liquid separation quickly,and improve concentration level.

  • TS,TJ,TV Series for the release of dissolved gas have the advanced technology properties in the follow:
  • 1.Be able to work effectively in low pressure of 0.2 MPa;
  • 2.The average bubbles diameter is from 20 to 30 microns;
  • 3.Gas release rate up to 99%.
>TS Series

TS-dissolved gas releaser has five models of different flow and role in different pressure:(HZ)

Model Pipe Interface Diameter(mm) Flow(m3/h) In Different Pressure(MPa) Role Dia.(mm)
0.10 0.20 0.30 0.40 0.50
TS-Ⅰ Æ15 0.25 0.32 0.38 0.42 0.45 250
TS-Ⅱ Æ20 0.52 0.70 0.83 0.93 1.00 350
TS-Ⅲ Æ25 1.01 1.30 1.59 1.77 1.91 500
TS-Ⅳ Æ25 1.68 2.13 2.52 2.75 3.10 600
TS-Ⅴ Æ32 2.34 3.47 4.00 4.50 4.92 700
>Configuration/ Features
  • Orifice-Porous Room-Small Parallel Disk Crack-Muzzle.
  • 1.Can release 99% of the dissolved gas above 0.15 MPa,diameter from 20 to 40μm,working under the pressure of 0.20 MPa;
  • 2.The hole box isn’t easy to plug,with single releaser of big flow and role scope.
>TJ Series

A movement spring in the TJ series releaser is drived to work(transmission through water- ejector and vacuum-puming pipe) by the pressure of the pump. Opening the gate at the back of water-ejector when the impurities has pluged the gas.

TJ-dissolved gas releaser has five models of different flow and role in different pressure:(HZ)

Type Model Pipe Interface Diameter Vacuum-Puming Pipe Interface Diameter Flow(m3/h) Role Dia. Weight
(kg)
0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50
TJ-I Æ15 -- -- 0.98 1.08 1.18 1.28 1.38 1.47 1.57 1.67 500 2.0
TJ-II Æ20 M31 M18.5 2.10 2.37 2.59 2.81 2.97 3.14 3.29 3.45 700 2.0
TJ-III Æ25 -- -- 4.03 4.61 5.15 5.60 5.98 6.31 6.74 7.01 900 4.8
TJ-IV Æ32 M45 M18.5 5.67 6.27 6.88 7.50 8.09 8.69 9.29 9.89 1000 8.6
TJ-V Æ48 M85 M18.5 7.41 8.70 9.47 10.55 11.11 11.75 - - 1100 9.0
>Configuration/ Features
  • Orifice-Single Porous Room-Big Parallel Disk Crack-Tongue Reed-Muzzle.
  • 1.Can release 99% of the dissolved gas above 0.15 MPa,diameter from 20 to 40μm,working under the pressure of 0.20 MPa;
  • 2.The hole box is easy to plug,with single releaser of small flow and role scope;
>Installation Notes
  • 1. Must first clean the pipes before installation.
  • 2. TJ-releaser could be installed on the contrary;
  • 3. water-ejector and control gates are installed in the appropriate place;
  • 4. Each water ejector to allow 8 to 10 TJ-releaser be connected;
  • 5. Should be installed flatly to prevent the uneven distribution of export flows;
  • 6. To install bend-pipe in the export if needs to change the direction of the gas-water,but the pipe not too long.
>TV Series

The vibration tray maintain the gap with the fixed tray at the best working conditions due to the spring pressure was fixed disk with the best working conditions to maintain the gap.Two materials of stainless steel and copper be used to prevent corrosion from the wastewater.

TV-dissolved gas releaser has three models of different flow and role in different pressure:(HZ)

Type Model(mm) Pipe Interface Diameter(mm) Flow(m3/h) Role Dia. Weight(kg)
0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 Copper Stainless Steel
TV-I Æ150 25 0.95 1.04 1.13 1.22 1.31 1.4 1.48 1.51 400   2.0
TV-II Æ200 25 2.00 2.16 2.32 2.48 2.64 2.8 2.96 3.12 600 2.5 3.5
TV-III Æ250 40 4.08 4.45 4.81 5.18 5.54 5.91 6.18 6.64 800 3.8 5.5
>Configuration/ Features
  • Orifice-Single Porous Room-Big Parallel Disk Crack With Up And Down.
  • 1. Can release 99% of the dissolved gas above 0.15 MPa,diameter from 20 to 40μm,working under the pressure of 0.20 MPa;
  • 2. The hole box is easy to plug,with single releaser of small flow and role scope;
>Installation Notes
  • After the elimination of big impurities can still use this:
  • 1. Firstly,putting pressure on the gas and water mixture to clean the impurities in the pipe,and then fix on the dissolved gas main pipe to the branch pipe and TV-dissolved gas releaser;
  • 2. Installation should be maintained for the releaser’s position of non-tilted;
  • 3. Corrosion-resistant rubber and the compressed air branch pipes should be connected tightly;
  • 4. TV-dissolved gas releaser shouldn’t be installed on the contrary.
>Order Notes

Please apprise us the model,dimension and the quantity.